{"product_id":"atrix-vacosmri-omega-supreme-mri-hospital-hepa-vacuum","title":"Atrix Omega Supreme MRI Hospital HEPA Vacuum – 1 US Gal","description":"\u003cp\u003eThe \u003cstrong\u003eAtrix Omega Supreme MRI Hospital Vacuum\u003c\/strong\u003e is a dry service vacuum supplied with a \u003cstrong\u003e1-US-gallon (3.78 L) HEPA cartridge\u003c\/strong\u003e, a 15 ft. non-metallic ESD-safe hose and service attachments. Atrix identifies this 120V, 628W configuration for medical-facility and MRI-equipment cleaning. Its long hose allows the operator to reach equipment while positioning the vacuum separately, subject to the manufacturer's restrictions and the facility's MRI safety procedures.\u003c\/p\u003e\n\u003ch2\u003eMRI Placement and Operating Restrictions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThe vacuum and power cord contain metal. This is not a claim of unrestricted MRI-room suitability.\u003c\/strong\u003e Atrix's exact-model MRI manual instructs users to keep the vacuum as far from the MRI machine as possible and outside the MRI room when possible. It also recommends having another technician hold the vacuum during operation when possible.\u003c\/p\u003e\n\u003cp\u003eThe manual marks the supplied \u003cstrong\u003e31651 power cord and AVPA016 shoulder strap\u003c\/strong\u003e as containing some magnetism and says they should be kept outside the MRI room. The hose and hose attachments are described as non-metallic. That description does not apply to the complete vacuum, cord or strap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNo numerical magnetic-field operating limit or formal MR Safe\/MR Conditional designation has been verified in the reviewed Atrix documentation.\u003c\/strong\u003e The 15 ft. hose length is not a certified safe separation distance. Obtain clarification from Atrix and approval from the facility's MRI safety authority for the proposed setup before MRI use. Read the \u003ca href=\"https:\/\/atrix.com\/wp-content\/uploads\/2020\/02\/999420_Omega-Supreme-Plus-MRI-Vacuum-Manual_2019.pdf\"\u003eVACOSMRI MRI instruction manual\u003c\/a\u003e before operation.\u003c\/p\u003e\n\u003ch2\u003eHEPA Collection for Dry Service Work\u003c\/h2\u003e\n\u003cp\u003eThe included \u003cstrong\u003eOF612HE cartridge is rated at 99.97% efficiency at 0.3 micron\u003c\/strong\u003e. The one-gallon cartridge uses 56-pleat media with cellulose, glass silicate and polyester layers. A filter plug is included for closing the cartridge inlet during changeout; unplug the unit and follow Atrix's removal and disposal instructions.\u003c\/p\u003e\n\u003cp\u003eHEPA filtration is a particle-filtration feature. It does not establish sterilization, disinfection, infection-control certification or approval for a regulated hazardous-material cleanup. Assess the material to be collected and the facility's procedures before use.\u003c\/p\u003e\n\u003ch2\u003eStatic Control and Service Reach\u003c\/h2\u003e\n\u003cp\u003eAtrix describes this exact model as ESD-safe, with a static path to ground, a non-metallic ESD-safe hose, crevice tool and flexible gooseneck tool. A built-in electronic line filter minimizes EMI\/RFI noise emissions. These features support static-sensitive service work while preserving the need for proper grounding and the equipment manufacturer's service precautions.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer publishes \u003cstrong\u003e99 CFM airflow and a 69 dB noise level\u003c\/strong\u003e. An Ametek Advantek II motor carries a manufacturer rating of 1,000 hours, and a resettable thermal cutout stops the unit if it overheats. The detachable 10 ft. power cord and 15 ft. hose provide placement options; they do not override MRI restrictions.\u003c\/p\u003e\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOne-gallon dry HEPA cartridge with verified 99.97% efficiency at 0.3 micron.\u003c\/li\u003e\n\u003cli\u003e15 ft. non-metallic ESD-safe hose and narrow-reach service attachments.\u003c\/li\u003e\n\u003cli\u003eStatic path to ground and built-in EMI\/RFI electronic line filter.\u003c\/li\u003e\n\u003cli\u003e120V configuration with detachable cord and resettable thermal cutout.\u003c\/li\u003e\n\u003cli\u003eFilter cartridge, filter plug and service accessories supplied with this exact model.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eAtrix Part Number\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOmega Supreme MRI service vacuum\u003c\/td\u003e\n\u003ctd\u003eVACOSMRI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120V detachable power cord\u003c\/td\u003e\n\u003ctd\u003e31651\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 ft. non-metallic ESD-safe hose\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-metallic ESD-safe crevice tool\u003c\/td\u003e\n\u003ctd\u003e31654\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-metallic ESD-safe flexible gooseneck tool\u003c\/td\u003e\n\u003ctd\u003e31657\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHEPA filter cartridge\u003c\/td\u003e\n\u003ctd\u003eOF612HE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter plug\u003c\/td\u003e\n\u003ctd\u003e410017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustable shoulder strap\u003c\/td\u003e\n\u003ctd\u003eAVPA016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe shoulder strap and cord are included but carry the MRI-room restrictions stated above. The table identifies package contents, not permission to take every component into an MRI room.\u003c\/p\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAtrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer model\u003c\/td\u003e\n\u003ctd\u003eVACOSMRI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum type\u003c\/td\u003e\n\u003ctd\u003eDry specialty service vacuum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e1 US gallon (3.78 L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical configuration\u003c\/td\u003e\n\u003ctd\u003e120V, grounded North American configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e628 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow\u003c\/td\u003e\n\u003ctd\u003e99 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise level\u003c\/td\u003e\n\u003ctd\u003e69 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eAmetek Advantek II; manufacturer-rated 1,000-hour motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded filter\u003c\/td\u003e\n\u003ctd\u003eOF612HE HEPA cartridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHEPA efficiency\u003c\/td\u003e\n\u003ctd\u003e99.97% at 0.3 micron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter construction\u003c\/td\u003e\n\u003ctd\u003e56 pleats; cellulose, glass silicate and polyester layers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHose\u003c\/td\u003e\n\u003ctd\u003e15 ft., non-metallic, ESD-safe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHose inside \/ outside diameter\u003c\/td\u003e\n\u003ctd\u003e1 in. \/ 1.25 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower cord\u003c\/td\u003e\n\u003ctd\u003e10 ft., detachable; 31651\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e20 × 6.25 × 9.25 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESD feature\u003c\/td\u003e\n\u003ctd\u003eStatic path to ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectronic line filter\u003c\/td\u003e\n\u003ctd\u003eBuilt-in EMI\/RFI noise-emission filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor protection\u003c\/td\u003e\n\u003ctd\u003eResettable thermal cutout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer warranty\u003c\/td\u003e\n\u003ctd\u003e3-year limited; subject to Atrix terms and exclusions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eIntended Applications and Dry-Use Limits\u003c\/h2\u003e\n\u003cp\u003eAtrix identifies medical-facility maintenance and MRI-equipment cleaning as applications for VACOSMRI. Any MRI-related use must first satisfy the manufacturer's restrictions and the facility's approved setup. Hospital use does not mean the vacuum disinfects, sterilizes or carries infection-control certification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDry indoor use only.\u003c\/strong\u003e Do not collect liquids or wet material or use outdoors, on wet surfaces or in wet environments. Do not collect burning or smoking items, or use with flammable or combustible liquids or where they may be present. Connect to a properly grounded nominal 120V, 50\/60Hz outlet; the MRI manual prohibits a plug adapter. Keep the filter installed and the lid securely latched.\u003c\/p\u003e\n\u003cp\u003eThis listing does not establish suitability or certification for asbestos, lead, silica, combustible dust or other hazardous-material collection.\u003c\/p\u003e\n\u003ch2\u003eReplacement HEPA Cartridge\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOF612HE\u003c\/strong\u003e is the included cartridge and is expressly listed as a replacement HEPA filter in the exact-model MRI manual. Replacement cartridges are sold separately. Confirm replacement hoses and accessories with Atrix for this precise configuration and MRI-use restrictions before ordering.\u003c\/p\u003e","brand":"Atrix","offers":[{"title":"Default Title","offer_id":48049002512468,"sku":"JQ522","price":870.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/2467\/3364\/files\/atrix-vacosmri-omega-supreme-hepa-vacuum-hose.webp?v=1793296637","url":"https:\/\/industrialtouch.ca\/products\/atrix-vacosmri-omega-supreme-mri-hospital-hepa-vacuum","provider":"Industrial Touch","version":"1.0","type":"link"}